Buy Fluke T6-1000 Electrical Tester with FieldSense Technology

Buy Fluke T6-1000 Electrical Tester with FieldSense Technology
Buy Fluke T6-1000 Electrical Tester with FieldSense Technology
Brand: Fluke
Product Code: FLUT6-1000
Availability: In Stock
Price: $344.85
Ex GST: $313.50

Available Options


Add Special Calibration Introductory Offer:

Qty:
  - OR -   Add to Wish List
Add to Compare

Measure voltage … without test leads

Measure voltage up to 1000 V ac through the open fork, without test lead contact to live voltage.+ Without opening covers or removing wire nuts. On wires up to AWG 4/0 (120 mm2), carrying as much as 200 A. It will change your job. Safer. Faster. Easier.

+ Voltage measurement requires capacitive path to ground, provided through user in most applications. Ground connection via test lead may be required in some situations.

 
     
 

Product Highlights

  • FieldSense technology for ac voltage, current and frequency measurement without making electrical contact to live voltage+
  • Simultaneous voltage and current display – shows all power supply measurements at a glance for efficient trouble shooting
  • 1 to 1000 V ac or dc (T6-1000)
  • 0.1 to 200 A ac
  • Resistance 1 Ω to 100 kΩ
  • Frequency measurement 45 Hz to 66 Hz
  • Works with wires up to AWG 4/0 (120 mm2) with a 17.8 mm jaw opening
  • HOLD button temporarily freezes the reading for easy viewing
  • Easy to read display with backlight
  • Accepts optional Fluke TPAK Magnetic Meter Hanger for convenient operation
  • Standard two-year warranty; extendable to 4 years through product registration within 45 days of purchase*

+ Voltage measurement requires capacitive path to ground, provided through user in most applications. Ground connection via test lead may be required in some situations.
* Register product online within 45 days of purchase to extend warranty to four years. See http://a.fluke.com/registration for details. Two-year additional warranty offer may be discontinued without notice

 
     
 
Measurement Specifications

Function

Requires test leads

Range

Resolution

Accuracy[1]

FieldSense 
ac voltage

No

1000 V

1 V

± (3 % + 3 counts) 45 Hz - 66 Hz[2][3]

FieldSense
ac current

No

200.0 A

0.1 A

± (3% + 3 counts) 45 Hz - 66 Hz

FieldSense
frequency (Hz)

No

45 Hz – 66 Hz

1 Hz

± (1% + 2 counts)[3]

Volts ac

Yes

1000 V

1 V

± (1.5% + 2 counts) 45 Hz - 66 Hz

Volts dc

Yes

1000 V

1 V

± (1% + 2 counts)

Resistance

Yes

2000 Ω

1 Ω

± (1% + 2 counts)

Yes

20.00 kΩ

0.01 kΩ

Yes

100.0 kΩ

0.1 kΩ

Safety

 

1000 V CAT III
600 V CAT IV

 

 

Accuracy[1]: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are ac-coupled, RMS responding.
Accuracy[2]: Add 3 % without an external ground connection. External ground connection required for user wearing insulated gloves, standing on an insulated ladder, or otherwise insulated from earth ground.
Accuracy[3]: FieldSense is specified from 16 V to 100 % of range.

 
General Specifications

Calibration

1-year calibration cycle

Dimensions

61.1 x 259.3 x 43.8 mm

Jaw opening

17.8 mm

Weight

0.35 kg (0.78 lb)

Temperature
Operating: 
Storage:

 

-10 °C to +50 °C (14 °F to 122 °F)
-30 °C to +60 °C (-22 °F to +140 °F)

Altitude
Operating: 
Storage:

 

2,000 m (6,562 feet)
10,000 m (32,808 feet)

Relative Humidity

0% to 90%, 5 °C to 30 °C (41 °F to 86 °F)
0% to 75%, 30°C to 40 °C (86 °F to 104 °F)
0% to 45%, 40°C to 50 °C (104 °F to 122 °F)

Battery Type and Life

2 x AA (IEC LR6); 360 hours continuous, typical; 200 hours using FieldSense

Temperature coefficient

0.1 x (specified accuracy) / °C for <18°C or >28 °C 
(< 64.4 °F or > 82.4 °F)

Safety

IEC/EN 61010-1: Pollution Degree 2

Electromagnetic Environment

IEC/EN 61326-1: Portable

 
     
 

Recommended Accessories

Fluke H-T6 Rugged Holster